References from Local composition distribution of the zeotropic mixture in heat exchangers of auto-cascade refrigeration system: numerical modeling and experimental validation. Local targets link to admitted publications; unresolved targets remain external evidence.
Novel zeotropic refrigeration cycles for air cooling with large temperature decrease
10.1016/j.enbuild.2022.112450 · 2022 · External reference
Limited options for low-global-warming-potential refrigerants
10.1038/ncomms14476 · 2017 · External reference
Performance evaluation of low GWP large glide temperature zeotropic mixtures applied in air source heat pump for DHW production
10.1016/j.enconman.2022.116457 · 2022 · External reference
Dynamic characteristics of a climate-adaptive radiant cooling and fresh air supply integrated system with zeotrope R290/R600a
10.1016/j.enconman.2024.118862 · 2024 · External reference
Proposal and performance study on a component-based double-stage compression auto-cascade refrigeration cycle
10.1016/j.enconman.2022.116566 · 2023 · External reference
A comprehensive analysis of binary mixtures as working fluid in high temperature heat pumps
2023 · External reference
Theoretical and experimental investigations on the changing regularity of the extreme point of the temperature difference between zeotropic mixtures and heat transfer fluid
10.1016/j.energy.2013.02.029 · 2013 · External reference
Progress of auto-cascade refrigeration systems performance improvement: composition separation, shift and regulation
10.1016/j.rser.2023.113664 · 2023 · External reference
Calculating circulation concentration of zeotropic refrigerant mixtures
1995 · External reference
Composition shift of a mixed-gas Joule-Thomson refrigerator driven by an oil-free compressor
2007 · External reference
Experimental research on the concentration distribution characteristics of dual-temperature refrigeration system using R290/R600a based on separation condensation
10.1016/j.ijrefrig.2021.06.024 · 2021 · External reference
Experimental investigation on the concentration distribution behaviors of mixture in an ejector enhanced auto-cascade refrigeration system
10.1016/j.ijrefrig.2018.11.024 · 2019 · External reference
A method for estimating the composition of the mixture to be charged to get the desired composition in circulation in a single stage JT refrigerator operating with mixtures
10.1016/j.cryogenics.2009.12.004 · 2010 · External reference
Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode
10.1016/j.cryogenics.2016.11.007 · 2017 · External reference
An analytical method for ensuring the optimal circulating composition of the multicomponent refrigerant mixture in a steady-state operation mode of the Joule-Thomson refrigerator operating with mixtures
10.1016/j.ijrefrig.2021.05.034 · 2021 · External reference
10.1016/j.applthermaleng.2021.117837
10.1016/j.applthermaleng.2021.117837 · External reference
Circulation concentration of CO2/propane mixtures and the effect of their charge on the cooling performance in an air-conditioning system
10.1016/j.ijrefrig.2006.06.008 · 2007 · External reference
Mixed refrigerant composition shift due to throttle valves opening in auto cascade refrigeration system
10.1016/j.cjche.2013.06.001 · 2015 · External reference
Study of the migration behavior of mixed refrigerants and energy efficiency during actuators action process in auto-cascade refrigeration systems
2025 · External reference
A novel method to measure the energy efficiency and performance of an auto-cascade refrigeration cycle
10.1016/j.applthermaleng.2023.121146 · 2023 · External reference
Unresolved reference
2002 · External reference
Local shifts of the fluid composition in a simulated heat pump using R-407C
10.1016/j.applthermaleng.2005.02.005 · 2005 · External reference
Concentration shift simulation for the mixed refrigerants R-404A, R-32/134a, and R-407C in an air conditioning system
10.1080/10789669.1997.10391368 · 1997 · External reference
Performance prediction of a refrigerating machine using R-407C: the effect of the circulating composition on system performance
10.1002/er.817 · 2002 · External reference
Local composition shift of mixed working fluid in gas-liquid flow with phase transition
10.1016/j.applthermaleng.2012.01.064 · 2012 · External reference
The influence of composition shift on organic Rankine cycle (ORC) with zeotropic mixtures
10.1016/j.enconman.2014.03.072 · 2014 · External reference
The discussion of composition shift in organic Rankine cycle using zeotropic mixtures
10.1016/j.enconman.2017.02.081 · 2017 · External reference
A strategy to optimize the charge amount of the mixed refrigerant for the Joule–Thomson cooler
10.1016/j.ijrefrig.2016.05.016 · 2016 · External reference
Local composition shift of refrigerant mixtures and its effect on cooling performance in a heat pump system
10.1016/j.enconman.2025.119809 · 2025 · External reference
Estimation of local composition in zeotropic mixtures and its application to heat pump system modeling
10.1016/j.applthermaleng.2025.127345 · 2025 · External reference
Correlations of void fraction for two-phase refrigerant flow in pipes
10.1016/j.applthermaleng.2013.12.032 · 2014 · External reference
Void fractions in two phase flow: a correlation based upon an equal velocity head model
10.1243/pime_proc_1969_184_051_02 · 1969 · External reference
Estimation of steady-state steam void-fraction by means of the principle of minimum entropy production
10.1115/1.3687113 · 1964 · External reference
A dimensionless correlation for determining the density of two-phase mixtures
1971 · External reference
Unresolved reference
External reference
Pressure gradients due to friction during the flow of evaporating two-phase mixtures in smooth tubes and channels
10.1016/0017-9310(73)90063-x · 1973 · External reference
An approximate generalized design method for multicomponent/partial condenser
1973 · External reference
Condensation inside and outside smooth and enhanced tubes — a review of recent research
10.1016/s0140-7007(02)00150-0 · 2003 · External reference
Comprehensive correlations for heat transfer during condensation in conventional and mini/micro channels in all orientations
10.1016/j.ijrefrig.2016.03.014 · 2016 · External reference
Heat flow rates in saturated nucleate pool boiling-a wide ranging examination using reduced properties
10.1016/s0065-2717(08)70205-3 · 1984 · External reference
A method for predicting heat transfer during boiling of mixtures in plain tubes
10.1016/j.applthermaleng.2015.06.047 · 2015 · External reference
Composition migration behavior in an auto-cascade refrigeration system with fractional and flash separation: charging, operation and regulation
2026 · External reference
A novel online measurement method for compositions and energy performance of an auto-cascade refrigeration system
10.1016/j.energy.2025.134780 · 2025 · External reference
Influence of fractional and flash separation on the suitable charge range of mixed refrigerants in an auto-cascade refrigeration system
2026 · External reference
Performance prediction of a refrigerating machine using R-407C: the effect of the circulating composition on system performance
10.1002/er.817 · ExternalCitation · doi-reference
Pressure gradients due to friction during the flow of evaporating two-phase mixtures in smooth tubes and channels
10.1016/0017-9310(73)90063-x · ExternalCitation · doi-reference
Local shifts of the fluid composition in a simulated heat pump using R-407C
10.1016/j.applthermaleng.2005.02.005 · ExternalCitation · doi-reference
Local composition shift of mixed working fluid in gas-liquid flow with phase transition
10.1016/j.applthermaleng.2012.01.064 · ExternalCitation · doi-reference
Correlations of void fraction for two-phase refrigerant flow in pipes
10.1016/j.applthermaleng.2013.12.032 · ExternalCitation · doi-reference
A method for predicting heat transfer during boiling of mixtures in plain tubes
10.1016/j.applthermaleng.2015.06.047 · ExternalCitation · doi-reference
10.1016/j.applthermaleng.2021.117837
10.1016/j.applthermaleng.2021.117837 · ExternalCitation · doi-reference
A novel method to measure the energy efficiency and performance of an auto-cascade refrigeration cycle
10.1016/j.applthermaleng.2023.121146 · ExternalCitation · doi-reference
Estimation of local composition in zeotropic mixtures and its application to heat pump system modeling
10.1016/j.applthermaleng.2025.127345 · ExternalCitation · doi-reference
Mixed refrigerant composition shift due to throttle valves opening in auto cascade refrigeration system
10.1016/j.cjche.2013.06.001 · ExternalCitation · doi-reference
A method for estimating the composition of the mixture to be charged to get the desired composition in circulation in a single stage JT refrigerator operating with mixtures
10.1016/j.cryogenics.2009.12.004 · ExternalCitation · doi-reference
Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode
10.1016/j.cryogenics.2016.11.007 · ExternalCitation · doi-reference
Novel zeotropic refrigeration cycles for air cooling with large temperature decrease
10.1016/j.enbuild.2022.112450 · ExternalCitation · doi-reference
The influence of composition shift on organic Rankine cycle (ORC) with zeotropic mixtures
10.1016/j.enconman.2014.03.072 · ExternalCitation · doi-reference
The discussion of composition shift in organic Rankine cycle using zeotropic mixtures
10.1016/j.enconman.2017.02.081 · ExternalCitation · doi-reference
Performance evaluation of low GWP large glide temperature zeotropic mixtures applied in air source heat pump for DHW production
10.1016/j.enconman.2022.116457 · ExternalCitation · doi-reference
Proposal and performance study on a component-based double-stage compression auto-cascade refrigeration cycle
10.1016/j.enconman.2022.116566 · ExternalCitation · doi-reference
Dynamic characteristics of a climate-adaptive radiant cooling and fresh air supply integrated system with zeotrope R290/R600a
10.1016/j.enconman.2024.118862 · ExternalCitation · doi-reference
Local composition shift of refrigerant mixtures and its effect on cooling performance in a heat pump system
10.1016/j.enconman.2025.119809 · ExternalCitation · doi-reference
Theoretical and experimental investigations on the changing regularity of the extreme point of the temperature difference between zeotropic mixtures and heat transfer fluid
10.1016/j.energy.2013.02.029 · ExternalCitation · doi-reference
A novel online measurement method for compositions and energy performance of an auto-cascade refrigeration system
10.1016/j.energy.2025.134780 · ExternalCitation · doi-reference
Circulation concentration of CO2/propane mixtures and the effect of their charge on the cooling performance in an air-conditioning system
10.1016/j.ijrefrig.2006.06.008 · ExternalCitation · doi-reference
Comprehensive correlations for heat transfer during condensation in conventional and mini/micro channels in all orientations
10.1016/j.ijrefrig.2016.03.014 · ExternalCitation · doi-reference
A strategy to optimize the charge amount of the mixed refrigerant for the Joule–Thomson cooler
10.1016/j.ijrefrig.2016.05.016 · ExternalCitation · doi-reference
Experimental investigation on the concentration distribution behaviors of mixture in an ejector enhanced auto-cascade refrigeration system
10.1016/j.ijrefrig.2018.11.024 · ExternalCitation · doi-reference
An analytical method for ensuring the optimal circulating composition of the multicomponent refrigerant mixture in a steady-state operation mode of the Joule-Thomson refrigerator operating with mixtures
10.1016/j.ijrefrig.2021.05.034 · ExternalCitation · doi-reference
Experimental research on the concentration distribution characteristics of dual-temperature refrigeration system using R290/R600a based on separation condensation
10.1016/j.ijrefrig.2021.06.024 · ExternalCitation · doi-reference
Progress of auto-cascade refrigeration systems performance improvement: composition separation, shift and regulation
10.1016/j.rser.2023.113664 · ExternalCitation · doi-reference
Heat flow rates in saturated nucleate pool boiling-a wide ranging examination using reduced properties
10.1016/s0065-2717(08)70205-3 · ExternalCitation · doi-reference
Condensation inside and outside smooth and enhanced tubes — a review of recent research
10.1016/s0140-7007(02)00150-0 · ExternalCitation · doi-reference
Limited options for low-global-warming-potential refrigerants
10.1038/ncomms14476 · ExternalCitation · doi-reference
Concentration shift simulation for the mixed refrigerants R-404A, R-32/134a, and R-407C in an air conditioning system
10.1080/10789669.1997.10391368 · ExternalCitation · doi-reference
Estimation of steady-state steam void-fraction by means of the principle of minimum entropy production
10.1115/1.3687113 · ExternalCitation · doi-reference
Void fractions in two phase flow: a correlation based upon an equal velocity head model
10.1243/pime_proc_1969_184_051_02 · ExternalCitation · doi-reference