Contact and support
Need help, have a question, or want to contact the ResearchHub team?
© 2026 ResearchHub. Built for responsible scholarly connection.
Research graph
References from Safety and efficacy of decompressed vertebroplasty in reducing pulmonary fat embolism: a proof-of-mechanism study in a sheep model. Local targets link to admitted publications; unresolved targets remain external evidence.
Osteoporosis treatment in patients undergoing spinal fusion: a systematic review and meta-analysis
10.3171/2021.3.focus2175 · 2021 · External reference
Current concepts in the management of osteoporotic vertebral fractures: a narrative review
10.31616/asj.2020.0594 · 2020 · External reference
Treatment of osteoporotic vertebral fractures
10.1016/j.otsr.2020.102779 · 2021 · External reference
Balloon kyphoplasty versus percutaneous vertebroplasty for osteoporotic vertebral body compression fractures: clinical and radiological outcomes
10.1016/j.spinee.2022.11.015 · 2023 · External reference
A prospective evaluation of percutaneous vertebroplasty in osteoporotic vertebral compression fracture patients
2023 · External reference
Comparing percutaneous vertebroplasty and conservative therapy for treating osteoporotic compression fractures in the thoracic and lumbar spine: a systematic review and meta-analysis
10.2106/jbjs.15.00425 · 2016 · External reference
Complications of percutaneous vertebroplasty: an analysis of 1100 procedures performed in 616 patients
10.1097/md.0000000000003850 · 2016 · External reference
Cost-effectiveness of cement augmentation versus no augmentation for the fixation of unstable trochanteric fractures
10.2106/jbjs.21.01516 · 2022 · External reference
An outline on the advancements in surgical management of osteoporosis-associated fractures
2024 · External reference
Complications of percutaneous vertebroplasty: a pictorial review
10.3390/medicina59091536 · 2023 · External reference
Current status and challenges of percutaneous vertebroplasty (PVP)
10.1007/s11604-022-01322-w · 2023 · External reference
Vertebroplasty and kyphoplasty for osteoporotic vertebral fractures: what are the latest data?
10.3174/ajnr.a5458 · 2018 · External reference
Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence
10.1016/j.wneu.2017.01.124 · 2017 · External reference
Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty
10.1186/s13018-019-1459-4 · 2019 · External reference
Risk factors for pulmonary cement embolism associated with percutaneous vertebral augmentation: a systematic review and meta-analysis
10.1016/j.ijsu.2022.106632 · 2022 · External reference
Early complications and cement leakage in elderly patients who have undergone intraoperative computed tomography (CT)-guided cement augmented pedicle screw placement: eight-year single-center experience
10.1016/j.wneu.2019.05.047 · 2019 · External reference
Risk factors for cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: an analysis of 1456 vertebrae augmented by low-viscosity bone cement
10.1097/brs.0000000000003773 · 2021 · External reference
Fatal cardiac perforation and pulmonary embolism of leaked cement after percutaneous vertebroplasty
10.1016/j.jflm.2019.03.004 · 2019 · External reference
Cement leakage following percutaneous kyphoplasty in a patient after a posterior lumbar fusion: a case report
10.1186/s12893-020-00733-8 · 2020 · External reference
Pulmonary embolism from cement augmentation of the vertebral body
10.4184/asj.2018.12.2.380 · 2018 · External reference
Fat embolism syndrome following percutaneous vertebroplasty: a case report
10.1016/j.spinee.2013.09.021 · 2014 · External reference
Single-case metanalysis of fat embolism syndrome
10.1016/j.ijcard.2021.10.151 · 2021 · External reference
Trends and associated outcomes of fat embolism after trauma surgery
10.1016/j.surg.2024.04.008 · 2024 · External reference
CT features and risk factors of pulmonary cement embolism after vertebroplasty or kyphoplasty in patients with vertebral compression fracture: a retrospective cohort study
10.21037/qims-22-569 · 2023 · External reference
Fat embolism syndrome complicated by diffuse alveolar hemorrhage after a minimally displaced tibia fracture: a case report
10.2106/jbjs.cc.23.00020 · 2023 · External reference
Complications of vertebroplasty in adults: incidence, etiology, and therapeutic strategies—a comprehensive, systematic literature review
10.3390/complications2030022 · 2025 · External reference
Asymptomatic and unrecognized cement pulmonary embolism commonly occurs with vertebroplasty
10.3174/ajnr.a2368 · 2011 · External reference
Impact of aspiration percutaneous vertebroplasty in reducing bone cement leakage and enhancing distribution—an ex vivo study in goat vertebrae
10.3390/bioengineering10070795 · 2023 · External reference
Pulmonary cement embolism associated with percutaneous vertebroplasty or kyphoplasty: a systematic review
10.1111/j.1757-7861.2012.00193.x · 2012 · External reference
Fatal fat embolism after vertebroplasty: identification of the high-risk patient
2006 · External reference
Percutaneous vertebroplasty for vertebral compression fractures with intravertebral cleft: cement injection under vacuum aspiration
10.1016/j.jvir.2011.08.021 · 2011 · External reference
Percutaneous vertebral augmentation using drill rotation for osteoporotic vertebral compression fractures with intravertebral vacuum cleft
10.1007/s00256-020-03437-5 · 2020 · External reference
The effect of mechanical aspiration of the vertebral body on pulmonary arterial pressure before cement injection in the vertebroplasty procedure
10.1177/2309499018762608 · 2018 · External reference
Clinical outcomes of fracture haemorrhage aspiration for percutaneous vertebroplasty in treating osteoporotic vertebral compression fractures
10.2147/jpr.s345760 · 2021 · External reference
Lavage prior to vertebral augmentation reduces the risk for cement leakage
10.1007/s00586-015-4191-8 · 2016 · External reference
Effect of unilateral pulsed jet lavage prior to vertebroplasty on the intravertebral pressure and cement distribution
10.1186/s13018-020-01779-3 · 2020 · External reference
Decompressed percutaneous vertebroplasty: a secured bone cement delivery procedure for vertebral augmentation in osteoporotic compression fractures
10.1016/j.injury.2012.10.017 · 2013 · External reference
Assessment of cement leakage in decompressed percutaneous kyphoplasty
10.3390/jcm13020345 · 2024 · External reference
Anatomy of the sheep spine and its comparison to the human spine
1997 · External reference
Comparison between sheep and human cervical spines: an anatomic, radiographic, bone mineral density, and biomechanical study
10.1097/00007632-200105010-00008 · 2001 · External reference
Percutaneous vertebroplasty: a new animal model
10.1016/j.spinee.2016.06.011 · 2016 · External reference
First-time systematic postoperative clinical assessment of a minimally invasive approach for lumbar ventrolateral vertebroplasty in the large animal model sheep
10.1016/j.spinee.2016.06.015 · 2016 · External reference
A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study)
10.1016/j.spinee.2019.07.009 · 2019 · External reference
Fat embolism and fat embolism syndrome
2019 · External reference
Spine surgery and fat embolism syndrome: defining the boundaries of medical accountability by hospital autopsy
10.52586/5067 · 2021 · External reference
Vertebral body lavage reduces hemodynamic response to vertebral body augmentation with PMMA
10.1177/2192568218803106 · 2019 · External reference
Systematic retrospective analysis of risk factors and preventive measures of bone cement leakage in percutaneous kyphoplasty
10.1016/j.wneu.2022.12.117 · 2023 · External reference
155. Safer way for vertebroplasty under fluid mechanics theory
10.1016/j.spinee.2020.05.566 · 2020 · External reference
Perioperative hidden blood loss in elderly osteoporotic vertebral compression fracture patients with percutaneous vertebroplasty and influencing factors
2021 · External reference