Research graph
References from Study on the characteristics of fire smoke spreading in contact nodes of urban cable tunnels. Local targets link to admitted publications; unresolved targets remain external evidence.
Real-scale CFD simulations of fire in single- and double-track railway tunnels of arched and rectangular shape under different ventilation conditions
10.1016/j.engstruct.2014.05.027 · 2014 · External reference
Study on temperature distribution and CO diffusion induced by cable fire in L-shaped utility tunnel
10.1016/j.scs.2020.102407 · External reference
Experimental study on flammability and flame spread characteristics of polyvinyl chloride (PVC) cable
10.3390/polym12122789 · External reference
Effects of interlayer distance and cable spacing on flame characteristics and fire hazard of multilayer cables in utility tunnel
10.1016/j.csite.2020.100784 · External reference
Cable tray FIRE tests simulations in open atmosphere and in confined and mechanically ventilated compartments with the CALIF3S/ISIS CFD software
10.1002/fam.2680 · 2019 · External reference
The flow of fire gases under a beamed ceiling
10.1016/0010-2180(81)90002-x · 1981 · External reference
Upward flame spread and critical conditions for pe/pvc cables in a tray configuration
10.3801/iafss.fss.4-433 · 1994 · External reference
Effects of ambient wind on thermal smoke exhaust from a shaft in tunnels with natural ventilation
10.1016/j.applthermaleng.2017.02.017 · 2017 · External reference
A comprehensive study on the critical ventilation velocity in tunnels with different geometries
10.1080/14733315.2015.11684088 · 2015 · External reference
Study on the mechanism of the influence of the crossing angle of tunnels and cross passages on the spread of fire smoke
2020 · External reference
Study on cable fire spread and smoke temperature distribution in T-shaped utility tunnel
10.1016/j.csite.2019.100433 · 2019 · External reference
Simulation study on value of cable fire in the cable tunnel
10.1016/j.proeng.2012.08.100 · 2012 · External reference
Study on dynamic risk assessment of cable fire in pipeline corridor based on FDS
2024 · External reference
Critical longitudinal ventilation velocity for smoke control in a tunnel induced by two nearby fires of various distances: Experiments and a revisited model
10.1016/j.tust.2020.103559 · 2020 · External reference
Characteristics of smoke extraction by natural ventilation during a fire in a shallow urban road tunnel with roof openings
10.1016/j.firesaf.2014.05.009 · 2014 · External reference
Experimental study on fire spread behavior of single 110 kV cable under different layout conditions
10.1016/j.firesaf.2023.103957 · 2023 · External reference
Improved assessment of fire spread over horizontal cable trays supported by video fire analysis
10.1007/s10694-018-0788-x · External reference
Cable tray fire tests with halogenated electric cables in a confined and mechanically ventilated facility
10.1002/fam.2717 · External reference
Experimental study on smoke temperature distribution under different power conditions in utility tunnel
10.1016/j.csite.2018.03.002 · 2018 · External reference