Dosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments
10.4103/0973-1482.31967 · 2007
Radiation field edge detection in portal images
10.1088/0031-9155/36/12/015 · 1991
Unresolved referenced work
2001
Testing of dynamic multileaf collimation
10.1118/1.597699 · 1996
Quality control aspects of the Philip multileaf collimator
10.1016/s0167-8140(97)00100-x · 1997
Quality control for multileaf collimator leaf position accuracy using amorphous silicon electronic portal imaging devices
10.5732/cjc.008.10665 · 2009
Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy
10.1118/1.599028 · 2000
A dosimetric calibration method for a double-focused multileaf collimator
10.1118/1.2766757 · 2007
IMRT delivery performance with a varian multileaf collimator
10.1016/j.ijrobp.2007.06.082 · 2008
Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy
10.1118/1.1367863 · 2001
Comparison of dosimetric characteristics of 120-leaf and 80-leaf multi-leaf collimators in a Varian linear accelerator for a 6-MV photon beam
10.1007/s12194-008-0032-3 · 2008
A quality assurance procedure for the Varian multi-leaf collimator
10.1088/0031-9155/42/2/014 · 1997
Evaluation of two methods of predicting MLC leaf positions using EPID measurements
10.1118/1.2335490 · 2006
EPID-based verification of MLC performance for IMRT and VMAT
10.1118/1.4752207 · 2012
Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques
10.1120/jacmp.v12i4.3645 · 2011
Verification of multileaf collimator leaf positions using an electronic portal imaging device
10.1118/1.1515760 · 2002
An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation treatments
10.1088/0031-9155/49/12/011 · 2004
Consequences of leaf calibration errors on IMRT delivery
10.1088/0031-9155/52/4/019 · 2007
An MLC calibration method using a detector array
10.1118/1.3218767 · 2009
Quality assurance of MLC leaf position accuracy and relative dose effect at the MLC abutment region using an electronic portal imaging device
10.1093/jrr/rrs038 · 2012
Commissioning and quality assurance for intensity-modulated radiotherapy with dynamic multileaf collimator: experience of the Pontificia Universidad Catolica de Chile
2004