Abstract
Contact and support
Need help, have a question, or want to contact the ResearchHub team?
© 2026 ResearchHub. Built for responsible scholarly connection.
Wang Xiaoxue, Jiani Wei, Jianwen Wang
Abstract
Authors
Institutions
Provenance
crossref
Confidence 100%
ror
Confidence 99%
No local reference links have been materialized yet.
No local citing links have been materialized yet.
Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050
10.1016/j.ophtha.2016.01.006 · 2016
Risk assessment for ectasia after corneal refractive surgery
10.1016/j.ophtha.2007.03.073 · 2008
Evaluation of a risk factor scoring system for corneal ectasia after LASIK in eyes with normal topography
10.3928/1081597x-20100212-02 · 2010
Corneal epithelial thickness profile in the diagnosis of keratoconus
10.3928/1081597x-20090610-06 · 2009
Effect of phacoemulsification and astigmatism corrected multifocal intraocular lens implantation on corneal astigmatism and visual quality in cataract patients
2019
Design of treatment protocol in refractive cataract surgery is important for postoperative visual outcomes
2017
Calculation of intraocular lens power: a review
10.1111/j.1755-3768.2007.00879.x · 2007
Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery
10.1016/s0886-3350(03)00243-8 · 2003
Comparison of Pentaeam and OrbscanIIz on posterior curvature topography measurements in keratoeonus eyes
10.1016/j.ophtha.2006.03.046 · 2006
ror
Confidence 99%
pubmed
Confidence 98%
europepmc
Confidence 96%
unpaywall
Confidence 95%
openalex
Confidence 95%
doaj
Confidence 92%
datacite
Confidence 0%
Central corneal thickness measurement with the pentacam scheimpflug system-optical low coherence reflectometry pachymeter and ultrasound pachymetry
10.1016/j.jcrs.2005.03.058 · 2005
Morphogeometric analysis for characterization of keratoconus considering the spatial localization and projection of apex and minimum corneal thickness point
10.1016/j.jare.2020.03.012 · 2020
Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device
10.1016/j.joco.2016.06.003 · 2016
SMILE versus implantable collamer lens implantation for high myopia: a matched comparative study
10.3928/1081597x-20200210-02 · 2020
Hyperopic SMILE Versus FS-LASIK: a biomechanical comparison in human fellow corneas
10.3928/1081597x-20210830-02 · 2021
Sources of error in intraocular lens power calculation
10.1016/j.jcrs.2007.10.031 · 2008
Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography
10.1016/j.jcrs.2011.04.033 · 2011
Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using Galilei, Pentacam, and Sirius devices
10.1097/ico.0000000000000119 · 2014
Repeatability, reproducibility, and agreement between three different Scheimpflug systems in measuring corneal and anterior segment biometry
10.3928/1081597x-20140815-02 · 2014
Central and midperipheral corneal thickness measured with Scheimpflug imaging and optical coherence tomography
10.1371/journal.pone.0098316 · 2014
Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers
10.1007/s10792-013-9780-0 · 2014
Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes
10.4103/ijo.ijo_729_16 · 2017
Repeatability of the sirius imaging system and agreement with the pentacam HR
10.3928/1081597x-20120619-01 · 2012
Total corneal astigmatism measurements: agreement between 2 rotating scheimpflug cameras
10.1097/ico.0000000000001117 · 2017
Dual versus single Scheimpflug camera for anterior segment analysis: precision and agreement
10.1016/j.jcrs.2012.06.049 · 2012
No additional external references are available.