Abstract
Rights: UNKNOWN · https://www.elsevier.com/tdm/userlicense/1.0/ · Source: journal-auto-sync:external:CROSSREF_ISSN
Contact and support
Need help, have a question, or want to contact the ResearchHub team?
© 2026 ResearchHub. Built for responsible scholarly connection.
Nicole Jaffrezic-Renault, Abdelhamid Errachid
Abstract
Rights: UNKNOWN · https://www.elsevier.com/tdm/userlicense/1.0/ · Source: journal-auto-sync:external:CROSSREF_ISSN
Authors
Institutions
No ROR-resolved institution is linked to this work yet.
Provenance
crossref
Confidence 100%
unpaywall
Confidence 95%
datacite
Confidence 0%
No local reference links have been materialized yet.
No local citing links have been materialized yet.
Incidence of venous thromboembolism in hospitalized patients vs community residents
10.4065/76.11.1102 · 2001
The epidemiology of venous thromboembolism
2003
Incidence of diagnosed deep vein thrombosis in the general population: systematic review
10.1053/ejvs.2002.1778 · 2003
A population based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism
10.1001/archinte.1991.00400050081016 · 1991
Diagnosis and Treatment of Deep Venous Thrombosis and Pulmonary Embolism
2003
Unresolved referenced work
Kept as external metadata until matched
10.1067/mem.2003.181
10.1067/mem.2003.181
Value of assessment of pretest probability of deep-vein thrombosis in clinical management
10.1016/s0140-6736(97)08140-3 · 1997
A simple clinical model for the diagnosis of deep vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process
10.1046/j.1365-2796.1998.00249.x · 1998
Plasma D-dimers in the diagnosis of venous thromboem-bolism
10.1001/archinte.162.7.747 · 2002
Can laboratory testing improve screening strategies for deep vein thrombosis at an emergency unit?
10.1111/j.1365-2796.1994.tb01048.x · 1994
Management of suspected deep vein thrombosis in outpatients by using clinical assessment and D-dimer testing
10.7326/0003-4819-135-2-200107170-00011 · 2001
Diagnosis of a first DVT in outpatients: interim analysis of a management study based on clinical evaluation and D-dimer results
1997
Assessment of deep vein thrombosis or pulmonary embolism by the combined use of clinical model and noninvasive diagnostic tests
10.1055/s-2000-13219 · 2000
Strategies for the safe and effective exclusion and diagnosis of deep vein thrombosis by the sequential use of clinical score, D-dimer testing and compression ultrasonography
10.1055/s-2000-13222 · 2000
Application of conducting polymers to biosensors
10.1016/s0956-5663(01)00312-8 · 2002
Imprint of sub-25 nm vias and trenches in polymers
10.1063/1.114851 · 1995
Imprint lithography with 25-nanometer resolution
10.1126/science.272.5258.85 · 1996
Recent developments in micromilling using focused ion beam technology
10.1088/0960-1317/14/4/r01 · 2004
Silicon microstructuring technology
10.1016/0927-796x(96)00190-8 · 1996
Nanoscaled Interdigitated Electrode Arrays for Biochemical Sensors
10.1016/s0925-4005(98)00128-2 · 1998
Measurement systems based on metal / dielectric nanostructures for electrochemical analyses
10.1016/s0928-4931(01)00469-6 · 2002
Voltammetry of redox analytes at trace concentrations with nanoelectrode ensembles
10.1016/j.talanta.2003.10.024 · 2004
Biomolecule immobilization on electrode surfaces by entrapment or attachment to elec-trochemically polymerized films
10.1016/s0956-5663(99)00024-x · 1999
Porspect of conducting polymers in molecular electronics
10.1016/s1567-1739(02)00217-1 · 2003
Biosensing and drug delivery by polypyrrole
10.1016/j.aca.2005.10.011 · 2006
Electrochemical Sensors Based on Conducting polymer – Polypyrrole (Review)
10.1016/j.electacta.2005.11.052 · 2006
Synthesis and applications of one-dimensional nano-structured polyaniline
10.1016/j.mseb.2006.07.037 · 2006
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
10.1021/cr0300789 · 2005
Unresolved referenced work
Kept as external metadata until matched
Immobilization of rhodopsin on a self-assembled multilayer and its specific detection by electrochemical impedance spectroscopy
10.1016/j.bios.2005.06.002 · 2006
Soft Lithography
10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · 1998
Fabricating arrays of single proteins on glass using microcontact printing
10.1021/jp0263424 · 2003
“Dip-Pen” Nanolithography
10.1126/science.283.5402.661 · 1999
Impedance spectroscopy: Over 35 years of electrochemical sensor optimization
10.1016/j.electacta.2006.04.025 · 2006
Immobilization of native membrane-bound rhodopsin on biosensor surface
10.1016/j.bbagen.2005.04.017 · 2005
Electrode-posited biotinylated polypyrrole as immobilization method for impedimetric immunosensors
10.1109/jsen.2004.832858 · 2004
Electrochemical impedance probing of DNA hybridisation on oligonucleotide-functionalised polypyrrole
10.1016/j.talanta.2005.04.069 · 2005
Sensitive immunodetection through impedance measurements onto gold functionalized electrodes
10.1385/abab:89:2-3:161 · 2000
Unresolved referenced work
Kept as external metadata until matched
10.1016/j.snb.2010.11.034
10.1016/j.snb.2010.11.034 · doi-reference
Non-destructive characterization of mechanical and structural properties of amorphous diamond-like carbon films 1
10.1016/s0925-9635(97)00337-3 · doi-reference
EPR study of hydrogen-related defects in boron-doped p-type CVD homoepitaxial diamond films
10.1016/j.diamond.2004.06.019 · doi-reference
Anodic stripping voltammetry of heavy metals at nanocrystalline boron-doped diamond electrode
10.1002/elan.200603834 · doi-reference