Abstract
Background and study aims
Sodium phosphate is a key component of bowel preparation regimen for colon capsule endoscopy (CCE), but may cause serious complications. The aim of this study is to evaluate the use of Gastrografin, substituted for sodium phosphate, in CCE bowel preparation.Patients and methods
In total, 29 patients (median age 64 years; 23 females) underwent CCE, covered by the national health insurance system of Japan. All had a history of laparotomy and/or previously incomplete colonoscopy. On the day before examination, patients ingested 1 L of polyethylene glycol + ascorbic acid with 0.5 L of water in the evening, and again the same laxative on the morning of examination. After capsule ingestion, 50 mL of Gastrografin diluted with 0.9 L of magnesium citrate was administered, and then repeated after 1 hour.Results
The capsule excretion rate was 97 % (28/29). The median colon transit time was 2 hours 45 minutes and rapid transit (Conclusion
Gastrografin can be an alternative to sodium phosphate in CCE bowel preparation regimen.