Abstract
Contact and support
Need help, have a question, or want to contact the ResearchHub team?
© 2026 ResearchHub. Built for responsible scholarly connection.
Kana Katakami, Hisanori Imai, Yasuyuki Sotani, Hiroko Yamada
Abstract
Authors
Institutions
No ROR-resolved institution is linked to this work yet.
Provenance
crossref
Confidence 100%
pubmed
Confidence 98%
europepmc
Confidence 96%
unpaywall
Confidence 95%
doaj
Confidence 92%
datacite
Confidence 0%
No local reference links have been materialized yet.
No local citing links have been materialized yet.
A new concept for vitreous surgery. I. Instrumentation
10.1016/0002-9394(72)90295-4 · 1972
27-gauge Twinlight chandelier illumination system for bimanual transconjunctival vitrectomy
10.1097/iae.0b013e3181607a0f · 2008
Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery
10.1016/j.ajo.2006.07.051 · 2007
Vitrectomy with an alternative instrument system
1975
Fluidics of single and double blade guillotine vitrectomy probes in balanced salt solution and artificial vitreous
10.1167/tvst.7.6.19 · 2018
Shovel and cut technique: beveled vitrectomy probes to address diabetic tractional retinal detachments
10.1097/iae.0000000000002938 · 2023
Case reports on removal of vitreous cortex remnants using a beveled vitrectomy probe in high myopia: the shovel and lift technique
10.21561/jor.2023.8.1.67 · 2023
A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery
10.1016/j.ophtha.2009.06.043 · 2010
Review of small gauge vitrectomy: progress and innovations
10.1155/2017/6285869 · 2017
25-gauge transconjunctival sutureless vitrectomy
10.1097/icu.0b013e328133889a · 2007
Comparison of 25, 23 and 20-gauge vitrectomy
10.1097/icu.0b013e328329eaea · 2009
Changes in corneal topography after 25-gauge transconjunctival sutureless vitrectomy versus after 20-gauge standard vitrectomy
10.1016/j.ophtha.2007.01.034 · 2007
Small gauge vitrectomy: operative techniques
10.1097/icu.0000000000000568 · 2019
20–, 23-, and 25-gauge vitreous cutters: performance and characteristics evaluation
10.1097/iae.0b013e31815ec2b3 · 2008
Small gauge vitrectomy: recent update
10.4103/0974-620x.111893 · 2013
Impact of different manufacturers and gauge sizes on the performance of backflush needle
10.1038/s41598-020-78668-6 · 2020
Comparative analysis of 23-, 25-, and 27-gauge forceps stiffness and related displacement
10.1177/1120672120926861 · 2021
Multicenter survey of sutureless 27-gauge vitrectomy for primary rhegmatogenous retinal detachment: a consecutive series of 410 cases
10.1007/s00417-019-04448-2 · 2019
Comparison of 25- and 27-gauge pars plana vitrectomy in repairing primary rhegmatogenous retinal detachment
10.1155/2018/7643174 · 2018
Surgical outcomes of 27-gauge vitrectomy for a consecutive series of 163 eyes with various vitreous diseases
10.1097/iae.0000000000001442 · 2017
Comparative study of 27-gauge vs 25-gauge vitrectomy for epiretinal membrane
10.1038/eye.2015.275 · 2016
Outcomes of transconjunctival sutureless 27-gauge micro-incision vitrectomy surgery in diabetic vitreous haemorrhage
10.12669/pjms.331.11617 · 2017
27-gauge vitrectomy
10.1159/000360449 · 2014
Age-dependent changes in the structure, composition and biophysical properties of a human basement membrane
10.1016/j.matbio.2010.03.004 · 2010
Does the presence of an epiretinal membrane alter the cleavage plane during internal limiting membrane peeling?
2010
No additional external references are available.